AquaSnap® 30AWH-P - For residential and light commercial applications
The new 30AWH-P monobloc air-to-water heat pumps with R290 natural refrigerant result from a successful combination of innovation and environmental stewardship for a high level of comfort all year round.
Designed for heating and cooling applications, these heat pumps are suitable for both new housing and renovations, for residential and light commercial applications.
Delivering high performance, the 30AWH-P range is compatible with low to medium temperature emitters (underfloor heating, fan coil units, hydronic cassettes, radiators, mixed installations, etc.), and with high temperature emitters for renovation applications (boiler replacements).
The monobloc 30AWH-P heat pump is designed for outdoor installation in an open area. Each unit is produced and tested at our Carrier plants located in Europe and delivered ready for operation.
R290 natural refrigerant - Minimizing environmental impact
For the innovative heat pump range AquaSnap 30AWH-P, Carrier has selected R290 natural
refrigerant (Propane), featuring an extremely low Global Warming Potential (GWP100 = 0,02).
With a zero ozone depletion potential (ODP) and a significantly lower refrigerant charge, compared with traditional refrigerants, R290 natural refrigerant represents an environmentally sustainable choice, reducing equivalent emissions of CO2 by 99,999 %.
All parts containing greenhouse gas are hermetically sealed, which helps to minimize the potential for leaks and does not require opening to make the system ready for operation.
Energy savings due to increased energy efficiency
AquaSnap 30AWH-P units improve energy efficiency when compared with standard refrigerant such as R410A. Due to this increased efficiency (SCOP up to 4,82 and SEER up to 5,34), the heat pump reduces the amount of energy needed for cooling and heating requirements.
Designed and made in Europe
Each unit in the AquaSnap 30AWH-P range, designed and manufactured in Europe at our
Carrier plants, is tested over several steps along the production line before packaging, for
top level quality.
An energy-valuable solution
All sizes of the 30AWH-P range feature the A+++ energy class for heating (OAT 7°C; LWT 35°C)* or A++ (OAT 7°C; LWT 55°C)*, offering high heating power with low energy consumption.
* The energy efficiency class range of this product category is from D up to A+++
Low noise operation
Carrier has carefully designed this innovative range to offer a low-noise solution without compromising its high performance under standard operational conditions.
The 30AWH-P features ErP rated sound power level starting at 49dB(A), and a night mode that can be activated by user.
From a distance of 5m, the 30AWH-P features a low sound pressure level starting at just 24dB(A)* on the smallest size thanks to the acoustic insulation on the metal panels
around the hydraulic and refrigerant modules.
* Sound pressure measured from a distance of 5 m (OAT +7°C, LWT +47/55°C), according to the EN 12102-1 European Standard, at ErP conditions.
Year round comfort
The AquaSnap 30AWH-P heat pump range can be used in a wide range of outdoor air temperatures, representing a sound solution for different climates.
As the graphs below show, in heating mode it can operate at an outdoor air temperature from -20°C. In cooling mode, it operates at up to +46°C, whilst delivering water at a stable temperature for cooling, heating and domestic hot water (DHW) production.
WUI mulit-function wired controller
- Included inside the unit for immediate start-up and use of the unit
- Intuitive icons to help avoid language barriers
- Occupancy mode (Home, Sleep, Away)
- Easy temperature control to set either air temperature or water temperature depending on system configuration
- Weekly timer function
- Two levels of access: end-user and technician
- Manages cascade system with up to 4 units
Carrier comfort management T300
Carrier Comfort Management T300 is an advanced room control, featuring a stylish and modern design, that thanks to the built-in Gateway allows the remote management of home comfort via Carrier Comfort Management App. Besides managing up to 3 zones via expansion PCB, the T300 advanced control can operate as a true System Manager for the heating and cooling generation system (intuitive management of the heat pump and full-electric system operation, as well as hybrid distribution). The screen graphics of Carrier Comfort Management T300 are easy to read and contain self-explanatory icons allowing an intuitive use.
BluEdge™ comfort service app
Service technicians can do commissioning, diagnostics and troubleshooting easily and intuitively using the BluEdge Comfort Service App, which is an additional benefit of the AquaSnap 30AWH-P.
AquaSnap 30AWH-P in cascade
AquaSnap 30AWH-P can be cascaded with up to 4 units for heating, cooling and domestic
hot water requirements in light commercial applications. Each of the units can individually
meet the requirements of the space in which it is installed.
Ideal for renovation and new housing
Space-saving and lightweight solution
Compact size and reduced weight are among the most distinguishing features of AquaSnap
30AWH-P on the market. In particular, due to its width of only 946 mm and its weight starting from just 79,3 kg, AquaSnap 30AWH-P can also be installed in small spaces.
Water flow temperature up to 75°C
With a high water flow temperature of up to 75°C, AquaSnap 30AWH-P is suitable for the replacement of oil and gas boilers. In addition, it can deliver more hot water and helps to avoid the need for direct electric immersion to sterilize the water, protecting from legionella.
Different terminal units
The range has been designed to deliver high performance, suitable for low to medium temperature emitters (floor heating, fan coil units, hydronic cassettes, radiators, mixed installations, etc.) up to high-temperature emitters for renovation applications (boiler replacement).
Safety
Low refrigerant charge and its hermetically sealed refrigerant circuit help minimize the potential for leaks. No need to open the refrigerant circuit to put the system into operation.
Robust component design helps to avoid any potential risks of refrigerant leaks.
Pressure sensor that detects any refrigerant leakage, whilst displaying the alarm code on the wired controller.
Gas separator installed on the leaving water pipe that further prevents any potential gas leakage from being released into the house.