Skip

ISH 2025 Contactor – Products, Exhibitors, Contacts

You can find the Interactive Hall Plan 2025 here.

Facot Chemicals S.r.l.

Aligel HC30 Bio

Description

Ready-to-use antifreeze liquid added with fluorescent leak detector. Aligel HC30 Bio, as permanent PROPYLENE GLYCOL-BASED antifreeze, does not contain amines, nitrites, phosphates, silicates and borates in its inhibition pack. Contrary, it has a long-term organic inhibition and compared to the common antifreezes it has a very high (doubled) alkaline stock. Easily biodegradable. Protection of Aligel HC30 Bio is suitable for all metals, especially aluminum, his alloys and copper, that are usually the main parts of a cooling or heating system. Specific for food plants and solar panels, diluted with demineralised water as expressly required by the technical Norm UNI 8065:2019.Moreover, thanks to its formulation it is compatible with all materials constituting heating pumps.

INSTRUCTION FOR USE: Clean carefully the interested parts of the system according to the UNI 8065:2019 norm in force; if needed make a pickling of the pipes with Ferronex or ZInconex-LQ in order to eliminate slags or welding residues. Introduce ALIGEL HC30 BIO into the circuit from the more available point. Make the system run cold for some hours and after the boiler is on, vent carefully from the point where there is scarce circulation.

FREEZE PROTECTION / BOILING POINTS: Freezing point of ALIGEL HC30 BIO is -32 °C. Boiling point is +104 °C to atmospheric pressure, up to a value of +160 °C with pressure 5 bar.

BEHAVIOUR AGAINST RUBBER SLEEVES AND PLASTIC PARTS: ALIGEL HC30 BIO, thanks to first distillation PROPYLENE GLYCOL basis and to the choice of additives in its inhibition pack is a very reliable food product against non-metal products making up a heat exchange circuit.

ALIGEL HC30 BIO CONFORMS TO THE FOLLOWING NORMS: ASTM D 3306 – Type 2 (propylene-glycol based antifreeze).

More products by Facot Chemicals S.r.l.

Trade fair innovation

Four-X One Shot

It is a unique concentrated product with 4 functions. It has a disintegrating action for sludge and slurries and also exerts a protective antiscale action in the presence of hard water, providing anticorrosive protection toward all constituent metals in systems, particularly aluminum and its alloys. It is also formulated with a powerful broad-spectrum biocide that can inhibit algal growth in low-temperature systems (e.g., radiant floors). The overall action is sanitizing and does not need to be flushed when used properly in conjunction with appropriate MAGNEX series magnetic defangment filter.

EFFECTIVENESS:
1. Restorative: breaks down and disperses any type of fouling present in thermal and refrigerant circuits, whether inorganic (rust, limestone, magnetite, machining residues, etc.) or organic (algae, biofilm, bacteria, etc.) in nature.
2. Antiscalant: the sequestering active ingredients in the formulation make it possible to keep calcium and magnesium salts dissolved in water in dispersion, thus preventing the precipitation of lime scale within the circuit as well as guaranteeing over time the correct heat exchange capacity of the system, preserving the system itself from possible occlusions and keeping consumption to a minimum.
3. Anticorrosive: the presence of a broad package of inhibitors formulated on the basis of azoles and molybdates allows the product to exert a prolonged anticorrosive action (even years after loading) toward all metals constituting the systems, particularly toward amphoteric metals such as aluminum and light alloys (aluminum-silicon).
4. Antibacterial: the broad-spectrum biocide present in the formulation, in addition to performing a preservative function of the product itself, makes it possible to preserve circuits running at low temperatures (30 ÷ 40 °C e.g., radiant floors, geothermal and refrigerants), from algal/bacterial proliferation resulting in algae stratification therefore cold areas in the house as well as higher energy consumption.

METHOD OF USE:
The product is recommended on medium-lived, even dated, but NOT compromised systems, in conjunction with a magnetic filter-deflector to be installed on the return to the boiler. Load directly from the filter, or via Disiflux sanitizing pump or an easy entry point of the system, at the rate of 0.5 %, i.e. 1 liter for every 200 liters of liquid circulating in the system. Periodic cleaning of the sludge-magnetic filter will be necessary and will depend on the amount of sludge in the circuit. Indicatively, a filter cleaning is recommended a few days after the product has been placed in the circuit, then 10 to 15 days apart, and then after more 30 gg repeating the operation for a few months. The amount of sequestered sludge as well as the turbidity of the water itself will tend to improve gradually after each inspection. Please consult Facot Chemicals Technical Department for more information and follow the requirements of UNI 8065:2019 for subsequent controls.

Paratex

Corrosion proofing insulating bands for the protection of underground and aerial mains or pipes.
Paraffinic, dielectric with a polyethylene film on one side.

APPLICATIONS:
To be used whenever pipes have to be protected by corrosion due to atmospheric, chemical,
environmental agents. Suitable also for the protection from stray currents of metal surfaces, for the
outer binding of tanks, underground, aerial and underwater mains or pipes. The band represents an
excellent steam barrier and thanks to its chemical inertia it is a good protection from the above
mentioned agents, too.
Paratex band has a quite total application versatily since it can be used in those points impossible
to reach, as for example curves, valves etc.

COMPOSITION:
Synthetic fibre fabric, that can not be altered by soil chemical, bacteriologic and mycotic agents;
it is impregnated with a corrosion proofing paste based on paraffinic hydrocarbons specially
treated and charged.

CHARACTERISTICS:
Once it has been applied, it keeps its plasticity and inalterability. It is waterproof (saline water too),
gasproof and it can be used at a temperature ranging from -50 °C to +50 °C.

COMPATIBILITY OF MATERIALS:
Paratex tape, thanks to its composition based on paraffin hydrocarbons is chemically inert and
therefore compatible with all materials used in buildings of all types including metal and plastic
polymers like PE, PP, PES, PVC, ABS, PU.

INSTRUCTIONS FOR USE:
Wind up the band overlapping 10/15 mm two following turns, then wear a glove for cold levelling
off, to obtain an homogeneous and flat surface. On rusted or irregular surfaces it is recommended
an accurate cleaning with a hard brush.