Sprinkler
Description
Duyar sprinkler is easy to use and extremely safe. Sprinkler is placed on the specially designed piping system such that iscovers the area requiring protection. One of the most significant components of the stuffing, the fluid in the glass tube expands and goes off due to the temperature generated by fire. Because the ambient temperature exceeds the maximum expected ambient temperature by 30°C during fire, the maximum ambient temperature of the sprinkler should be shosen tobe at temperatures above 30°C. Once the glass tube of the sprinkler above fire, the water under pressure hits the deflect and sprayed over fire. Only the sprinkler heating up during fire goes off, thereby releasing water.Duyar Valve Sprinkler Product List;
(For technical details, please check fire product catalogue)
Standart Sprey Sprinklers - Standart & Quick Response
- Pendent
- Upright
- Sidewall
ECLH Standart and Quick Response
- Pendent
- Sidewall
Elo Sprinklers Standart and Quick Response
- Pendent
- Upright
Pendent Sprinklers
They are preferred in suspended ceilings or in locations where downward sprinklers are appropriate. Water sprays in a conically expansion. They can be used with escutcheons.
Pendent -Standart Response.
K Factor: K5.6(80), K8.0(115) Thread size: ½” NPT (15 mm), ¾” NPT (20 mm) /Response : Standard response Finished :Brass, Chrome, White Temperature: 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Pendent Sprinkler -Quick Response
K Factor: K5.6(80), K8.0(115) Thread size : ½” NPT (15 mm), ¾” NPT (20 mm) Response : Quick response Finished : Brass, Chrome, White Temperature : 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Upright Sprinkler
Mounted in locations without suspended ceilings with the deflector pointing upwards. The water hits the deflector and sprays downwards with a conical expansion. It can be used for wet, dry and pre-action systems.
Upright Sprinkler - Standard response
K Factor : K5.6(80), K8.0(115) Thread size : ½” NPT (15 mm), ¾” NPT (20 mm) Response : Standard response Finished : Brass, Chrome Temperature : 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Upright Sprinkler - Quick response
K Factor : K5.6(80), K8.0(115) Thread size : ½” NPT (15 mm), ¾” NPT (20 mm)
Response : Quick response
Finished : Brass, Chrome
Temperature : 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Side Wall Sprinkler They are preferred in suspended ceilings or in locations where downward sprinklers are appropriate. Water sprays in a conically expansion. They can be used with escutcheons.
Side Wall - Standart Respons
K Factor : K5.6(80), K8.0(115) Thread size : ½” NPT (15 mm), ¾” NPT (20 mm) Response : Standard response Finished : Brass, Chrome, White Temperature : 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Side Wall - Quick Respons
K Factor : K5.6(80), K8.0(115)
Thread size : ½” NPT (15 mm), ¾” NPT (20 mm)
Response : Standard response
Finished : Brass, Chrome, White
Temperature : 57˚C(135˚F), 68˚C(155˚F), 79˚C(175˚F), 93˚C(200˚F), 141˚C(286˚F)
Address
Duyar Vana Makina San. ve Tic. A.S.
Osmangazi Mah. 2653 Sok. No: 7
Duyar 34522
Marmara/Istanbul
Türkiye
Telephone+90 6681808